BeyondERP.Newsletter
Menu

Setup page · Production control

Configure production floor execution

A setup page where you create the named configurations that control how the production floor execution interface behaves on a device, from sign-in and tab selection to the options shown when workers report progress.

Used by
Payroll administrator, Manufacturing execution workload shop supervisor, Shop supervisor and 2 more roles
Business process
Consume resources
Menu item
JmgProductionFloorExecutionConfigurationV2
Main table
JmgProductionFloorExecutionConfiguration
Setup steps
1 on this page
Show what matters for
PAGE GUIDEWhat the page does and how to use it8 sections. Choose a role to highlight what matters to you.
Everyone

1What it is and why

What it isA setup page where you create the named configurations that control how the production floor execution interface behaves on a device, from sign-in and tab selection to the options shown when workers report progress.
What you do hereUse this page to add a configuration and set its General, Tab selection, Login, Main view and Report progress options (such as clock-in only, lock employee, single worker, search, license plate generation and label printing), and later choose that configuration on each shop floor device.
ExampleFor example, a device in the company hall gets a clock-in and clock-out only configuration, while a device on the shop floor lets machine operators start and complete jobs and register breaks.
Configure production floor execution page in Dynamics 365
The page in Dynamics 365. page title tab to open what to set or check
Functional consultant · Solution architect

2Where it fits

Business processRun production operations › Consume resources
Menu pathProduction control › Setup › Manufacturing execution › Configure production floor execution
Set up firstFeature management Microsoft Learn Time registration workers Microsoft Learn
Used next byProduction floor execution (device setup) Microsoft Learn
Related pagesDesign the production floor execution interface Microsoft Learn Document routing Microsoft Learn
End user · Functional consultant

3How to do it

About the examples: Examples and screenshots in this guide use BEAT, a demo company in a Dynamics 365 test environment. Use your own company's codes and values instead of copying them.

Setup steps on this page

Configure production floor execution

Use this page to add a configuration and set its General, Tab selection, Login, Main view and Report progress options (such as clock-in only, lock employee, single worker, search, license plate generation and label printing), and later choose that configuration on each shop floor device.

Steps from Microsoft

  1. Go to Production control > Setup > Manufacturing execution > Configure production floor execution.
  2. On the Action Pane, select New.
  3. In the Configuration field, enter a unique name (it cannot be changed later) and optionally a Description.
  4. On the General FastTab, set options such as Clock in and out only, Report quantity at clock-out, Lock employee, Use the actual time of registration and Single worker.
  5. On the Tab selection FastTab, add and arrange the tabs the interface should show.
  6. Set the Login, Main view and Report progress FastTab options, including Generate license plate and Print label.

Source: Microsoft Learn

Fields on the page

FieldWhat it meansTable column
Clock in and out onlyReduces the interface to clock-in and clock-out; Tab selection must be empty first.Microsoft Learn ClockInAndOutOnly
Report quantity at clock-outPrompts workers to report feedback on jobs in progress when they clock out.Microsoft Learn SignOutFeedback
Lock employeeSet to No to sign workers out after each registration. Set to Yes to keep them signed in.Microsoft Learn LockEmployee
Use the actual time of registrationStamps each registration with the submit time rather than the sign-in time.Microsoft Learn UseActualTimeOfRegistration
Single workerFor a device used by one worker; removes badge sign-in and uses the linked system user account.Microsoft Learn EnableSingleWorker
Enable searchAdds a search field for job ID or order ID, by keypad or bar code.Microsoft Learn Scanner
Generate license plateGenerates a new license plate from the warehouse number sequence on each report as finished.Microsoft Learn GenerateLP
Print labelPrints a license plate label on report as finished using document routing.Microsoft Learn PrintLabel

Test checklist

  1. Create a configuration with Lock employee and Use the actual time of registration set to Yes, and add tabs on Tab selection.
  2. Open the production floor execution interface on a device and select the configuration and a job filter.
  3. Sign in as a worker, start a job some minutes later and check the registration time is the submit time, not the sign-in time.
  4. Report progress and check the job card journal on the production order.

Source: Microsoft Learn

Functional consultant

4Setup decisions

Setup stepRecommended value and whyDecision, common mistake and test
Configure production floor executionUse the actual time of registration = Yes on any configuration where Lock employee or Single worker is YesLearn says you will usually want Use the actual time of registration set to Yes when Lock employee and/or Single worker is Yes, because workers stay signed in for long periods and the sign-in time would otherwise be used.Typing a provisional configuration name. The name must be unique and can't be edited later, so a wrong name means creating a new configuration and reselecting it on each device.

Feature management and licence

Feature to turn onRegister material consumption as complete and edit dimensions on the production floor execution interface (Optional)Material list on the production floor execution interface (Optional)Tracked components (Optional)

Microsoft Learn

Solution architect

5Design impact

Can it be undoneReversible: Options can be changed any time and apply to the next registrations. The configuration name can't be edited. Device references are cleaned up after 60 days of inactivity or with Clean up client configurations. Microsoft Learn
If you change it laterA configuration name cannot be changed after it is created, and device references to configurations are cleaned up automatically after 60 days of inactivity or manually with Clean up client configurations. Microsoft Learn
Technical architect

6Technical

Menu itemJmgProductionFloorExecutionConfigurationV2 Checked in Dynamics 365
FormJmgProductionFloorExecutionConfigurationV2 Checked in Dynamics 365
TableJmgProductionFloorExecutionConfigurationShown as “PRODUCTION FLOOR EXECUTION CONFIGURATION” in Record infoChecked in Dynamics 365
Who can open itPrivilegesMaintain the supervisor-only Production floor execution pages JmgProductionFloorExecutionConfigurationMaintainDutiesEnable manufacturing execution process JmgManufacturingExecutionProcessEnableEnable time and attendance process JmgTimeAttendanceProcessEnableMaintain time supervision JmgTimeSupervisionMaintain
5 security rolesPayroll administrator HcmPayrollAdministratorManufacturing execution workload shop supervisor JmgManufacturingExecutionWorkloadSupervisorShop supervisor JmgShopSupervisorProduction manager ProdProductionManagerProduction supervisor ProdProductionSupervisor
Checked in Dynamics 365
Roles to set it up and use itTo set it up or change itProduction supervisor ProdProductionSupervisorShop supervisor JmgShopSupervisorProduction manager ProdProductionManagerManufacturing execution workload shop supervisor JmgManufacturingExecutionWorkloadSupervisorPayroll administrator HcmPayrollAdministratorGive people one of these roles. On this system, 5 roles can open this page.Checked in Dynamics 365
Actions on the page(Action Pane without tabs): Cleanup client configurations, Design tabsChecked in Dynamics 365
Developer

7Developer

Open it by URLhttps://<your-environment>/?mi=JmgProductionFloorExecutionConfigurationV2
Everyone

8Sources